0 items in your basket
Total £ 0.00 EX VAT
Mobile Fume Extractors
Extraction Arms & Fans
Plymovent Extraction Fans
Plymovent Hose Tube Arms
Plymovent Metal Tube Arms
Plymovent Plastic Tube Arms
Plymovent Extraction Arm Accessories
Stationary Filter Units
Spark Arrestors
Extraction Tables
Control Equipment
FlexHood
Filters & Spare Parts
Extraction Arm Spare Parts
Stationary Filter Unit Spares
Mobile Filter Unit Spares
Plymovent Fan Spares
Plymovent Extraction Table Spare Parts
Plymovent Filters
Environment Diluter System
Easy Solutions For Source Extraction
Mobile / Portable Solutions
Stationary Solutions
Stationary Solutions with Filter Units
Downdraft Tables
Machine Tool Applications
RPE Air Fed Helmets
Aeroguard Air Quality Monitor
Shop 55,000 Products
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
Pack of 10 (Part Number: 220993) 105A Mechanised Hypertherm Shields.
Straight answers to the questions people ask when buying plasma torch consumables in multi-packs.
In most plasma torches the nozzle and electrode wear fastest, because they create and constrict the arc. A drop in cut quality is usually the first sign. The shield mainly protects and cools the other parts from molten spatter, and the swirl ring and retaining caps usually wear more slowly.The order depends on the work, the number of pierces and the air quality, so keep notes of how long yours last. Check the swirl ring and caps for cracks, burns and blocked holes when you change the nozzle and electrode.
Yes, this is the usual advice. They wear together, and mismatched old and new parts tend to cut inconsistently. Maker guidance and trade guides say that when the electrode shows wear that needs replacing, the nozzle should be replaced with it.Packs of the individual parts make this easy to do every time. Look at the shield and swirl ring when you change them. A shield can often be cleaned of spatter and reused, and should be replaced if it is physically damaged.
Wipe parts with a clean, lint-free cloth and use clean air to clear debris, especially from the retaining cap. If you wash parts, use clean tap water; never use water from a cutting table.Some O-rings need a thin film of the lubricant the maker specifies, applied only if they look dry. Wipe off any excess, as too much can block gas flow. Fit parts in the correct order, tighten the electrode as the manual describes, and never refit worn parts.
Usually yes. Makers supply drag-cutting consumables for handheld work, designed so the shield can rest on the workpiece. Mechanised consumables are made for a machine-mounted torch, and some systems also include unshielded or gouging sets for particular jobs.Part numbers for handheld and mechanised cutting differ even on the same power source, and one is not a substitute for the other. Check the consumable chart for the way you use your torch.